+86-10-88861975/88861977   Fax: +86-10-88861976
中文EN
Home > Product > Power Inverter > Vehicle USE

CRV-1000B-1600B Series

Operation mode:Input:12/24VDC ; Output:220V Single-Phase

Application area:RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle,

Submit online

Submit online
  • Name:
  • *phone:
  • Telephone:
  • Company:
  • *E-mail:
  • Remarks:
  • Product overview
  • Characteristic
  • Application
  • Technical

Different from normal inverter, CRV Series vehicle-mounted inverter is designed for vehicle. In the light of the functional features of vehicle, the inverter's structure was designed and could withstand vibration for long time when vehicle is running(the inverter passed the vibration test in the lab in X. Y. Z three directions.)  CRV inverter could run in -40°C-+50°C (90% humidity) with full load. The battery isolators could be installed inside the inverter.

The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient. The inverter and life battery will not damaged by load, environment and rough usage cause various protection functions. The inside power components have low calorific value and the cooling fans are no need to long time run, so users will not be disturbed by the noise from fan.

1.Low frequency Pure sine wave for output.

2.The output voltage of inverter could not decreased with the capacity of battery lower or the capacity of load increase cause the inverter's power is sufficient

3.Low loss.

4.The inverter could be with instantaneous 3 times rated load at least. The air-condition, fridge and air pump could be used.

5.Digital and LED display is direct, simple and visual. User will not be disturbed by light or sound if press the mute and extinction button.

6.The type of battery could be chose;

7.The charging current could be chose;

8.The inverter could be started even no battery with normal AC.

9.Various protection functions: over charging, over discharging, over load, over temperature inside inverter, over temperature for life battery and output short and so on.

10.Various type of generator could be connected with input of inverter.

11.According to reality, the battery isolators could parallel or separate the vehicle battery and life battery.

12.Residential water and sweage level test switch for water pump function, (optional)


RV, Motor home, Ambulance, Bloodmobile, Rescue ambulance, Physical examination vehicle, Dental vehicle, Food&Drug testing vehicle, Military &Police vehicle, Media outside broadcasting vehicle, Helicopter, Yacht,etc.

Technical Parameters
ModelCRV1000BCRV1200BCRV1600B
Rated   Power(25℃)1000W/1250VA1200W/1500VA1600W/2000VA
Rated   Power(40℃)1000W/1250VA1200W/1500VA1600W/2000VA
Peak Power3000W3600W4800W
Various   combinations
System   voltage(DC)12V24V12V24V12V24V
1 ON,2 ONOAOAOAOAOAOA
1 OFF.2OFF50A30A50A30A60A40A
1ON,2OFF(factory   default)30A20A30A20A30A20A
1 OFF,2ON10A10A10A10A10A10A
Inverter   Mode
Rated Voltage12VDC/24VDC
Output PowerNominal Value
Output   Voltage220V/110V (110V Need to be   customized)
Output   Frequency50Hz/60Hz (60Hz Need to be   customized)
Output   WaveformPure sine wave
Efficiency>85%
Peak Factor3:1
Overload   Capacity100%-120%>1 min auto   shut; 120%-150%>30s auto shut;above 150% 10s auto shut:
Overload   ProtectionBattery   undervoltage protection, battery undervoltage protection, battery   undervoltage shutdown protection,
     output short circuit protection,   inverter overtemperature protection, backup battery over temperature   protection
Type of loadResistive load, inductive   load, capacitive load and half wave load
AC   Mode
Input Voltage   Range160VAC-270VAC±5V(Beyond the   range into the inverter mode)
Input   Frequency Range38-65Hz(Beyond the range   into the inverter mode)
Charging   Voltage14.4V ±0.2V ( 12V System   )/28.8V ±0.2V(24V System)
Charging   Current(12V)0A.10A,30A,50A(factory   default30A)0A,10A,30A,60A(factorydefault30A)
Charging   Current(24V)0A.10A,20A,30A(factory   default20A)0A,10A.20A.40A(factorydefault20A)
Overload Protection The over current protector   is disconnected after overload
Other
The inverter could be started in AC without battery. Generator:   All kinds of generator could be used(The power of generator is 1.5 times of   inverter's.)
Switching   TimeAC to DC 5 10ms; DC toACi   10ms
Protection   ClassIP20
Cooling   MethodForced air cooling
Water level   monitoringOptional
TemperatureOperating temperature: -40℃   〜50°C ; Storage temperature:-40℃ ~60℃
Working   Humidity0%〜95%
Noise level<40dB(1m)
No-load loss8-9W
Display   Informationworking status,the voltage   and frequency of input and output,the capacity of battery,the capacity of   load,fault alarm
Product   Size(mm)371(411)x230x135mm
Package   Size(cm)56.5x26.0x24.0cm
Netv/eight   (kg)11.3kg13.3kg15.3kg
Gross weight   (kg j13.3kg15.3kg17.3kg
Backup Timebackup time(H)=battery   capacity(Ah)÷discharge current(A)
Battery modeExternal battery
Battery typeLead-acid maintenance-free   battery(including deep cycle battery)/GEL battery / Lithium polymer battery

Note:“Output power” decreases as altitude increases,for example, 1500m the output power=rating power*0.94, 3500m the output power=rating power*0.82。

        The date in the table above defaults to lead-acid maintenance-free batteries.

        Specially available AC115V, AC120V, AC127V.


Tel:+86-10-88861975/88861977   Fax: +86-10-88861976 Email: renjingzhu@263.net Add:Room 8B, 2# Block A, Golden Resource Business Center, HaiDian Beijing China
Copyright© 2002-2021   Beijing Prostar International Electric Co., Ltd.   www.prostarele.com