Operation mode:12/24VDC
Application area:Most types of lead acid batteries including Calcium,GEL and AGM.
►Microprocessor Control (CPU);
►7-stage automaticcharging;
►This is a fully automatic battery charger with 7 charge tages;
►Automatic charging protects your battery from being overcharged. So you can leave the charger connected to the battery indefinitely;
►7-stage charging is a very comprehensive and accurate charging process that gives your battery longer life and better performance compared to using traditional chargers;
►7-stage chargers are suitable for most battery types including Calcium, Gel and AGM batteries. They may also help restore drained and sulphated batteries;
Types of batteries: Most types of lead acid batteries including Calcium,GEL and AGM.
P/No. | VCA-1205 | VCA-1207 | VCA-1210 | VCA-1212 | VCA-1215 | VCA-1220 | VCA-2405 | VCA-2410 |
Type | 7-Stage automatic | |||||||
Input Voltage | 220-240V-,50Hz/110V~60Hz | |||||||
Input Power | 154W | 215W | 307W | 332W | 415W | 554W | 296W | 547W |
Output Voltage | 12VDC | 12VDC | 12VDC | 12VDC | 12VDC | 12VDC | 24VDC | 24VDC |
Output Current | 5,000mA | 7,000mA | 10,000mA | 12,000mA | 15,000mA | 20,000mA | 5,000mA | 10,000mA |
Minimum Start Voltage | 2V | 2V | 2V | 2V | 2V | 2V | 4V | 4V |
Current Fuse Rating | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A | 250VAC,T3,15A |
CHARGE CONTROL | ||||||||
Desulphation | Pulse charger up to 11V | Pulse charger up to 22V | ||||||
Soft Start | Half the rated set current up to 12V | Half the rated set current up to 24V | ||||||
Bulk 5A(upto 14.4V) 7A(upto 14.4V) 10A(upto 14.4V) 12A(upto 14.4V) 15A(upto 14.4V) 20A(upto 14.4V) 5A(upto28.8V) 10A(upto28.8V) | ||||||||
Absorption | Constant voltage until current drops to 0.75A | Constant voltage until current drops to 1.05A | Constant voltage until current drops to 1.5A | Constant voltage until current drops tol.8A | Constant voltage until current drops to 2.25A | Constant voltage until current drops to 3.0A | Constant voltage until current drops to 0.75A | Constant voltage until current drops to 0.75A |
Battery Test | Monitors voltage for 90 seconds | |||||||
Recondition | Constant voltage (0.75A) up to 16V for 4hours | Constant voltage (1.05A) up to 16V for 4hours | Constant voltage (1.5A) up to 16V for 4hours | Constant voltage (1.8A) up to 16V for 4hours | Constant voltage (2.25A) up to 16V for 4hours | Constant voltage (3.0A) up to 16V for 4hours | Constant voltage (0.75A) up to32V for 4hours | Constantvoltage (1.5A) up to32V for 4hours |
Float | 13.8V also with pulse feature | 27.6V also with pulse feature | ||||||
Efficiency | App.85% | |||||||
Short Protect | Short Circuit Protection | |||||||
Polarity Reverse | Polarity Reverse Circuit Protection | |||||||
Non battery link Protection | Circuit Protection | |||||||
Link battery type mistake | Circuit Protection | |||||||
Over Voltage Protection | 17.5V | 35.0V | ||||||
Thermal Protect | 65℃±5℃ | |||||||
Cooling Fan | Automatic temperature controlled | |||||||
BATTERY RANGE | ||||||||
Deep Cycle | 35-100Ah | 50-140Ah | 70-200Ah | 80-240Ah | 100-300Ah | 134-400Ah | 35-100Ah | 70-200Ah |
Types of Batteries | Most types of lead acid batteries including Calcium. GEL and AGM | |||||||
Dimension(LxWxHmm) | 190x115x62 | 190x115x62 | 190x115x62 | 215x115x62 | 215x115x62 | 215x115x62 | 215x115x62 | 215x115x62 |
Weight(kg) | 1 | 1.03 | 1.1 | 1.1 | 1.2 | 1.2 | 1.1 | 1.2 |
Internal fuses should only be replaced by qualified elevtrical appliance repairer