Operation mode:Single Phase: 0.75-2.2kW ; Three phase:0.75~15kW
Application area:
Excellent current control capability, Ensure that the inverter doesn't trip during the process of fast acceleration.
The overexcitation function is automatically added in the deceleration process, deceleration time is shorter.
Strong over modulation capability, the output voltage is higher at the same input voltage.
Strong overload suppression capability, Ensure that the inverter does not stop due to overload fault at the maximum outpu. ting and dyeing, packaging, printing, pharmaceutical, food, reflow and production line etc.
Built-in industry-specific macro parameters, Support one-click setting of industry parameters;
Support external keyboard (LED keyboard);
Side by side installation, guide rail installation;
Support keyboard parameter copy.
PR6800 is a small size smart inverter product, It can be widely used in woodworking carving, glass edge grinding, food filling, medicine centrifuge, automatic production line, electronic equipment, logistics equipment and small automated mechanical equipment etc.
Specification | W | W1 | H | Hl | D | DI | Mounting hole diameter(φ) |
PR6800-0004T3G | 80 | 68 | 150 | 138 | 136.5 | 133 | 5 |
PR6800-0007T3G | |||||||
PR6800-0015T3G | |||||||
PR6800-0022T3G | |||||||
PR6800-0004S2G | |||||||
PR6800-0007S2G | |||||||
PR6800-0015S2G | |||||||
PR6800-0040T3G | 106 | 94 | 200 | 188 | 148.5 | 144.6 | 5.5 |
PR6800-0055T3G | |||||||
PR6800-0022S2G | |||||||
PR6800-0022T2G | |||||||
PR6800-0075T3G | 108 | 96 | 217 | 205 | 167 | 163 | 5.5 |
PR6800-0110T3G | 145 | 133 | 277 | 267 | 178 | 171 | 5.5 |
PR6800-0150T3G |
Item | Specification |
Rated voltage/Frequency | Three-phase,380V-440Vac;50Hz/60Hz |
Allowed voltage range | Single/three phase 220V(-15%)~240V(+10%) Three phase380V(-15%)-440V(+10%);Voltage unbalance rate:<3%;Frequency:±5% |
Rated voltage(V) | 0 〜inputvoltage |
Frequency | 0Hz~650Hz |
Overload capacity | 150% rated current for 60s |
Control mode | V/F mode |
Range ofspeed regulation | 1:100 |
starting torque | 150% rated torquewhen 0.5Hz |
Speed control accuracy | <±0.5% rated synchronousspeed |
Frequency accuracy | Digital set:max.frequency*±0.01%; Analogset:max.frequency*±0.2% |
Frequency resolution | Digital set:0.01Hz;Analogset: max.frequency*0.1% |
Torque rise | Auto torque ascension manual torque ascension 0.1%-30.0% |
V/F curve | Fourways:l kind of usersetV/Fcurveway3 kindsofdroptorque characteristic curve way(2.0 times power,1.7times power, 1.2 times power |
Acceleration/deceleration curve | One waysdine acceleration/deceleration four acceleration/deceleration timewith the unitoftime(minute/second)optionalmaxtimesetlO hours DC bra king start |
DC braking | frequency:0.00Hz~60.00Hz;braking |
Jogging | time:。.0 〜60.0s; braking current:0.0~150.0% |
Multi-speed operating | JogfrequencyrangeD.10Hz-50.0Hz |
Built-in PID | It can be realized by interior-PLC or control terminal Beconvenientto make closed-loop control system |
Auto energy-saving running | Accordingto load condition,V/F curve can beoptimized automaticallyto gettheaim of energy-saving running. |
Auto energy adjustment(AVR) | when the voltage of network changes,the output voltage can be automatically kept constant |
Auto current limiting | Du ring the operation, the current is automatically limited to prevent frequentflowtofaluttrip |
Runningcommand channel | Operation panel,control terminal and communication portcan be switched through many ways |
Frequency given channel | Digial given, analog voltage given,analog current given,pulse given communication port givencan be switched through many ways |
Auxiliaryfrequency given channel | Realize flexible auxiliary frequency fine-tu ring and frequency combination operation |
Pulseoutputterminal | 0-10kHz pulse square wave signal output,can realize output setting frequency and output frequency ect. |
Analog output terminal | 2waysanalogoutput.010v.0-20mAto getoutputof physical quantity such as settingfrequency and outputfrequency |
LEDdisplay | It can display settingfrequency,output frequency,output voltage,output currentandsoon |
Protection function | Phase-loss protection(optional),over current protection,over voltage protection, undervoltage protection over heat pratectionoverload etc. |
Service location | Indoor,not suffer from sun,dust,corrosive gas,oilfog, steam and so on |
Altitude | Less th an 1000m (derating at higher than 1000m) |
Environ merit temperature | -10℃~+40℃(Derating usein40℃~50C) |
Humidity | Less than 90%RH, no condensation |
Vibration | Lessthan 5.9m/s2(0.6g) |
Sto ra ge te m p e ra t u re | -40℃~+60℃ |
Protection class | IP20 |
Cooling way | Froced air cooling |